BS EN 1364-1 PDF

OF BOARD PARTITION SYSTEM. Client.: PalmEco Tech Ltd. Project.: Fire Resistance Test on Board Partition System in accordance with BS EN BS EN specifies a method for determining the fire resistance of non- loadbearing walls. This European Standard is used in. Find the most up-to-date version of BS EN at Engineering

Author: Tygokus Grojind
Country: Bahrain
Language: English (Spanish)
Genre: Marketing
Published (Last): 20 April 2013
Pages: 221
PDF File Size: 17.66 Mb
ePub File Size: 17.16 Mb
ISBN: 941-1-87896-745-9
Downloads: 33026
Price: Free* [*Free Regsitration Required]
Uploader: Tygojora

BS EN 1364-1:2015

According to the standard, different design solutions may not be mixed in a test such as different types of glass if it does not conform to the design solution used in practice. The deformation of the wall shall be measured for later use as a basis for assessments.

For vertical constructions there are also other functional requirements that can be used for classification.

Fire dampers SS-EN Walls European fire test bbs for non-load-bearing walls. Some countries, such as Sweden and Germany, require shock resistance, in this case shock tests must be performed according to EN Want access to British Standards?

EN Fire resistance tests for non-loadbearing elements – Part 1: Walls_Ecosafene

The Amber document status indicator indicates that some caution is needed when using this document – it is either: Click here to find out how to access this document. National authorities in the member states may choose not to use all classes why it is important to check which classes are of interest before testing. Document Status Indicators The Green document status indicator indicates that the document is: EN Fire resistance tests for non-load-bearing elements — Part 1: The Red document status indicator indicates that the document is an old version The document has likely been withdrawn by the publisher, also the meta data presented here may be out of date as it is no longer being maintained by the editorial teams at NBS.

  EURYDICE JEAN ANOUILH PDF

This document Older versions.

Again there may be more recent versions of the document. The method is also applicable to windows. This part of EN specifies a method for determining the fire resistance of non-load-bearing walls. Walls No longer current but cited in Building Regulations guidance. Otherwise, a vertical side should be free em the remaining three sides will be attached as in practice.

Radiation can be measured on vs test items for E-Class and on test items having uninsulated areas greater than 0. For constructions with an anticipated insulation performance, thermocouples are mounted on the non-exposed side for measurement of average temperature and maximum temperature.

The tested ej must be constructed as in practice. Covers equipment, test conditions, specimen and installation, test procedure and report. Their committees work with the manufacturing and service industries, government, businesses and consumers to facilitate the production of British, European and International standards.

BS EN – Fire resistance tests for non-loadbearing elements. Walls

Would you like to find out more about this test? If, in practice, the width or height of the construction is 3 m or less, then that dimension of the test specimen shall be tested at full size.

  DAVID GISSEN SUBNATURE PDF

The method can be applied to non-load-bearing inner walls with or without glazing, walls consisting mostly of glass and other inner or outer walls with or without glazing. Intended fire resistance Time minutes.

The standard is to be applied in conjunction with EN Free to use BIM project management tool provides step-by-step help to define, manage and validate responsibility for information development and delivery at each stage of the asset life cycle in level 2 BIM projects.

If, in practice, the construction is less than 3×3 m, the wall must be 136-41 in the same way as in practice.

EN 1364-1 Fire resistance tests for non-load-bearing elements – Part 1: Walls

The classification standard EN defines the classes that can be used in Europe and the classes in the table below can be applied to non-load-bearing walls. The integrity of the structure is measured as usual with interpreters, cotton pad and visual observations. For determining the fire resistance of non-loadbearing walls and can be applied to internal and external non-loadbearing walls with and without glazing.